Radiation furnace
Special ceramic anchoring
Adopting high-performance ceramic fiber board and precision anchoring technology, it is more effective in preventing heat loss.
Electric heating power control system
The electric heating power is all controlled by bidirectional thyristor, achieving stepless smooth adjustment of load power between 0 and 100%, making temperature control more accurate.
The PID control method in the multiplication mode achieves the optimal target temperature control system, and heats the glass more evenly.
Modular combined wind grille
The modular combination wind grille has convenient horizontal adjustment and strong recoverability.
Wind spot scanning, fully staggered design of wind eye, light wind spot and uniform tempered stress.
Wind grid double threaded screw lifting system
The lifting and lowering of the wind grille adopts screw drive, which can open and close quickly, and the positioning accuracy can reach 0.3mm.
High flow fan: Shanghai General Motors
The motor adopts a direct connection method, which is reliable, durable, energy-saving, and has a low failure rate.
Inverter brands: Mitsubishi, Schneider.
Technical parameters: